Fire Resistant Paint For Wall, Gypsum, Concrete

UGAMCOAT 07022007 System is tested and certified for 2 hour rating by Government of India's National Test House Mumbai.
Tested and Approved By UK LAB - Exova Warring ton fire

 

FEATURES:
It is specially prepared for getting fire retardant properties in walls. Generally cement walls are not flammable but when there is fire on one side, the temperature is conducted or radiated though the walls and when the temperature rises above 200 degreed C on other side, the products like paper gets self ignited. To prevent such heat transfer, these type of intumescent coatings are used. These are useful on cement, concrete, gypsum, fiber board partitions etc. Suitable on walls, plastered surface, asbestos, cement sheets, textured finishes. This is water base coating hence is ecofriendly.

HOW IT WORKS:
It forms foam when temperature reaches 250 degrees Celsius. This foam is heat and fire resistant and almost non conductive. During the foam forming reaction, some inert gasses are released. These gasses keep Oxygen away from wall. The foam thus formed keeps the surface away from heat and hence does not allow the surface to receive or conduct the heat in other areas. Also since this forms foam and a charred layer, it does not allow oxygen to reach to the surface over which it is applied. Hence it protects the surface from catching fire. UGAMCOAT 07022007 requires its UGAM FIRE RETARDANT PRIMER to be applied first, followed by application of UGAMCOAT 07022007 to the specified thickness with respect to rating required and then finally two coats of UGAM F R TOPCOAT WALL.

APPLICATION PROCEDURE:
First clean the surface with emery papers. In case old paint or primer which is not fire rated is applied to the wood, remove it with paint remover or mechanically.  Then apply single coat of UGAM F R PRIMER for wall, gypsum. The primer can be thinned down with pure clean soft water. Primer can be applied with brush or spray.  Then after minimum four to six hours interval apply first coat of UGAMCOAT 07022007 with brush, roller or airless spray to the surface. Allow four hours for drying.  Then apply second coat of UGAMCOAT 07022007 to the surface and again allow four to six hours for drying. Likewise go on applying the coats of UGAMCOAT 07022007 to the surface till you achieve dry film thickness of 700 microns for one hour rating OR 1500 microns for two hours rating. Minimum five coats of UGAMCOAT 07022007 will be applied to wall for one hour fire rating with interval of 6 hours. Minimum eight coats of UGAMCOAT 07022007 will be applied to wall for two hour fire rating with interval of 6 hours. After application of final coat of UGAMCOAT 07022007 to the surface allow 24 hours curing.  Then apply first coat of UGAM F R TOPCOAT WALL in desired color shade over UGAMCOAT 07022007 for protecting fire retardant coating from weather. Allow it to cure for six hours and apply second coat of UGAM F R TOPCOAT WALL. This can be applied with roller, brush or spray. The surface will now be ready after 12 hours for regular use. This coating is warranted for five years or first incidence of fire from the date of application. In case surface is exposed to fire, the coating should be re-applied to the surface. The final dry film thickness will be around 900 microns for one hour fire rating. Final dry film thickness will be around 1800 microns for two hour rating.

PROJECTS COMPLETED

 

CLIENT NAME

CLIENT NAME

Anandrishiji Hospital & Medical Research Center

O N G C - for offshore and onshore

Steel Strips Wheels Ltd.

New P C N D T buildings

ITC Hotel Hyderabad

C-Net Solution

Bharat Forge Ltd.

Playboy cafe

Elpro Estates Ltd.

Kokal Interior Contracts Pvt Ltd

Bengal DCL Housing Development Company Ltd.

K P M G Ltd

Volkswagen India Ltd.

Tube Products India Ltd

Barclays Technology Center

Mahindra and Mahindra Ltd

Goel Ganga Developers

Aquapharm Chemicals Pvt. Ltd.

B P C L and H P C L for all India depots

ENH Interior Projects – Manikchand Icon

Mahindra Defense land system

Rank Cranes

Gravity Chemicals

VerGo Pharma Research Laboratories Pvt. Ltd.

Phoenix Mall

Innvenue Hospitality Management Pvt. Ltd. - Ishanya Mall

S R Enterprises

Phadnis Infrastructure

Rahi Systems

Conserve Consultant & Engineers

Madhav Enterprise

M/s Thermal Systems (Hyderabad) Pvt. Ltd.

Eclat Engineers

S.S. INSULATION

Industrial Electric Services

Varad Enterprises - Kalyani Global

Pinks  Engineers

ITC Hotel Kolkata

 

OUR FIRE RETARDANT COATING UGAMCOAT 07022007 FOR WALL IS CERTIFIED BY EXOVA WARRINGTONFIRE LABS UK. PLEASE FIND THE LINKS BELOW.

https://drive.google.com/folderview?id=0BzQju9hjSaqRa2oySzBtTjd2QXM&usp=sharing

LIVE DEMO OF OUR FIRE RETARDANT PAINTS FOR WOODEN HOUSE, STRUCTURE STEEL, ELECTRICAL CABLES.

https://www.youtube.com/watch?v=kjEfB8ijBtQ

 

You can Email us on sales.ugamchem@gmail.com or contact us on +91-7219872619.

Feel free to get in touch for further queries, if any. 

The technical specification is correct to the best of our knowledge and under test conditions and we do not accept any liability towards misuse and contents of it. Product must be tested for specific use prior to use.

 

LEADER PAINTS MARKETING

FIRE RETARDANT INTUMESCENT PAINT SYSTEM FOR WALL

For 2 hour fire rating

For 1 hour fire rating

SR. NO.

HSN CODE

COATINGS

PRODUCT NAME

DFT Reqd.

No. of Coats

Coverage / Ltr

DFT Reqd.

No. of Coats

Coverage / Ltr

1

32089029

PRIMER

UGAM F R PRIMER FOR WALL

50 Microns

Single Coat

75 Sq. Ft.

50 Microns

Single Coat

75 Sq. Ft.

2

32089029

BASECOAT

UGAMCOAT 07022007 FOR WALL

1600 Microns

8-9 Coats

6 Sq. Ft.

700 Microns

4-5 Coats

15 Sq. Ft.

3

32089029

TOPCOAT

UGAM F R TOPCOAT FOR WALL

150 Microns

2 Coats

35 Sq. Ft.

150 Microns

2 Coats

35 Sq. Ft.